transportation

Due to the nature of airports, train terminals, and harbors being high-profile and historical targets for terrorism coupled with their often large window to wall ratio and nearly 24/7 operation, the priorities in Transportation Facilities anticipated by Edge window film are as follows:

  • Energy – as with other market segments, energy savings continues to be the primary historical reason the transportation and aviation industries consider window film. While offering energy savings and improved comfort with safety and security, operators and travelers benefit from the installation of energy-saving solar control window film from Edge.
  • Storm – operators, employees, and travelers are at high risk for property and personal loss due to high-energy storms. As with office buildings, operators are left to replace carpeting, drywall, and furnishings after a storm breaks out windows and these financial losses caused by water inside the building envelope can dwarf the cost of replacing the glass itself. In addition to the cost and inconvenience is the possibility of losing a secure perimeter.
  • Blast – in transportation and aviation the blast scenario can be either intentional or accidental. However, the cost in a blast scenario is typically in lives rather than dollars and cents. Although many buildings do not consider themselves targets of terrorism, transportation and aviation is in the unfortunate industry segment that is a stated and repeated target of terrorism

ProductSilver 20Silver 30Silver 40Cool Alloy 20Cool Alloy 35Cool Alloy 60UltraView 5UltraView 15UltraView 25UltraView 35Bronze 20Bronze 35
Visible Light Transmission19%30%44%20%35%60%6%14%27%38%17%34%
Visible Light Reflectance (Ext)56%43%28%29%17%9%56%48%27%13%37%23%
Visible Light Reflectance (Int)56%42%27%31%18%10%15%21%14%8%42%27%
Shading Coefficient0.260.370.50.410.560.750.230.290.470.630.220.39
Solar Heat Gain Coefficient (SHGC)0.230.320.440.350.480.650.200.250.40.550.190.34
SHGC (30 ° Angle)0.220.320.440.350.480.650.200.250.40.550.190.34
SHGC (60 ° Angle)0.20.280.390.320.430.580.180.230.360.490.170.3
Total Solar Energy Rejected (TSER)78%68%56%65%52%35%80%75%60%45%81%66%
U-Value0.90.920.951.031.051.070.960.960.991.020.90.91
Relative Heat Gain (BTU/h/ft2)63841139412516558701051405590
Solar Transmission14%22%34%18%33%54%10%15%28%42%10%25%
Solar Reflectance (Ext)53%42%29%26%16%8%53%47%29%14%56%39%
Solar Reflectance (Int)66%45%32%30%18%10%44%43%28%15%62%44%
Solar Absorption34%36%37%56%52%37%37%39%44%44%34%36%
UV Rejection>99%>99%>99%>99%>99%>99%>99%>99%>99%>99%>99%>99%

[toggle title=’

  • Clear Safety and Security Films
  • National Account Assistance Program
  • Attachment Systems Available
  • Safety and Security Training Available
  • Protection against debris in natural and man-made disasters
  • Secure the safety of people and protection of property

‘ open=”no”]

ProductGUARDIAN 4GUARDIAN 8GUARDIAN SILVER 8GUARDIAN 12
Visible Light Transmission89%87%17%87%
Visible Light Reflectance (Ext)9%9%55%9%
Visible Light Reflectance (Int)10%9%55%9%
Solar Heat Gain Coefficient (SHGC)0.850.830.220.80
Total Solar Energy Rejected (TSER)15%17%78%20%
UV Rejection>99%>99%>99%>99%
Film Thickness0.004"0.008"0.008"0.013"
ConstructionSingle PlyMulti-PlyMulti-PlyMulti-Ply
Tensile Strength25,000 psi25,000 psi25,000 psi25,000 psi
Break100 p/inch200 p/inch200 p/inch300 p/inch
Elongation150%150%150%150%
Peel5.5 p/inch5.5 p/inch5.5 p/inch5.5 p/inch
Puncture Strength68.2 pounds129 pounds129 pounds175 pounds
Puncture PropogationNT7.5 poundsNTNT
Tensile Strength at Yield14,000 psi15,000 psi15,000 psi15,000 psi
ANSI Z97.1Cat B (150 ft-lb)Cat A (400 ft-lb)Cat A (400 ft-lb)Cat A (400 ft-lb)
CPSC CFR 1201, Cat 1PassPassPassPass
CPSC CFR 1201, Cat 2Not TestedPassPassPass
LABCCompliantNTNTNT
EN126002B21A11A11A1
ASTM E 84 Surface BurnPassPass - "A" RatedPass - "A" RatedPass - "A" Rated
[/fusion_toggle]

ProductClear Defense™ 4Clear Defense™ 6
Visible Light Transmission89%89%
Visible Light Reflectance (Ext)9%10%
Visible Light Reflectance (Int)9%10%
Solar Heat Gain Coefficient (SHGC)0.840.83
Solar Absorption10%13%
Total Solar Energy Rejected (TSER)16%17%
UV Rejection>99%>99%
Film Thickness0.004"0.006"
Tensile Strength25,000 psi25,000 psi

ProductWhite FrostBlack OutWhite Out
Visible Light Transmission75%0%13%
Visible Light Reflectance (Ext)20%6%87%
Visible Light Reflectance (Int)22%6%84%
Shading Coefficient (SC)0.840.340.25
Solar Heat Gain Coefficient (SHGC)0.720.280.21
Solar Absorption11%90%38%
Total Solar Energy Rejected (TSER)28%72%79%
U-Value1.031.031.03
UV Rejection>99%>99%>99%
Solar Transmission69%0%17%
Solar Reflectance (Ext)20%8%45%